Absolute volumetric flow and total consumption, Temperature of the fluid, Absolute pressure, G type four different thread connection options; DN8, DN15, DN20 and DN25 Fast response time: 0.1 sec Integrated display showing actual volumetric flow and absolute pressure value, Analog 4... 20 mA and Pulse output, Modbus RTU or M-Bus communication option, A phone or tablet app for remote wireless sensor settings is included with the sensor. It has a built-in data logger that can record 8 million measurement samples at 1 data log per second. ...
The thermal mass flow direction switch can be used in compressed air and non-corrosive gases to determine the flow direction. The sensor element is of robust construction and made entirely of stainless steel. 1/2" G-type ball valve allows easy installation and pipe connection under pressure. Flow and direction information is provided via open relay switches. The signals are transmitted to other flow meters or valves. ...
Specially designed for harsh environments where direct measurement of consumption and standard flow rate is required. The case allows for all harsh weather conditions. All parts in contact with the measuring medium are made of 316 L stainless steel. Gases that can be measured include compressed air, various gases such as Nitrogen (N2), Oxygen (O2), Argon (Ar), Carbon Dioxide (CO2), Natural Gas, Propane, Butane or a mixture of gases such as Hydrogen, Methane gas. Optional Ex-Proof product, (Flow meter suitable for hazardous environments) Available for a wide range of pipe sizes. There are no moving parts, so it does not cause any blockage. Wireless interface available for sensor settings in the field (Bluetooth feature) 2 analog outputs (4-20 mA) and 1 pulse output Fieldbus interface: HART, Modbus Hazardous approval ATEX: II 2 G Ex i IIC T4 Two-way measurement Flow conditioning ...
It measures according to the Thermal Mass measurement principle and provides highly accurate measurement results. Displays flow and total consumption values for compressed air and other gases. The IP65 enclosure provides robust protection in industrial areas, even in poor environmental conditions. It has a fast response time and high measurement accuracy. Isolated 4..20 mA and Pulse output signals or Modbus RTU/TCP protocols can be selected. Selectable gas type (Some gases require special gas calibration), The sensor can be calibrated for mixed gases. Connection for pipe diameters from 1/2" to 12", optionally larger diameter connection, Optional color display showing volumetric flow and total consumption directly on the sensor, Atex certified model designed for use in explosive areas can be offered as an option. ...
The measurement is almost independent of density, viscosity, temperature, pressure and conductivity. Two measuring points inside the pipe and no moving parts to avoid pressure losses and pipe blockage. Electrically conductive liquids and liquids with low solid content can also be measured. Simple piping design: 5D up and down 2D 2D flat area of the pipe for 2D installation demands. It can self-diagnose to check the magnetization signal, empty tube and contaminated electrode. Accuracy: 0.3%、0.5%、1.0 Flow range: 0.1~10 m/s Current output: 4-20mA / 700Ω Pulse output: max NPN / 200mA / 32Vdc Alarm output: max NPN / 50mA / 32Vdc Communication Interface: RS-485 Modbus Measurable flow range ...
Speed of compressed air or O2, CO2, Ar, Propane, Butane, Natural Gas, LPG gases. (m/s) Volumetric flow of compressed air or these gases.(m³/h) and total consumption. (m³) The IP67 enclosure provides ultra-rugged protection against all harsh industrial conditions. Optional ATEX certified product, can be used in EX environments. All sensor parts in contact with the measurement are made of 316L stainless steel. Stainless pipe diameter from 1/2'' to 3'' No moving parts, no blockages. 2 analog outputs (4-20 mA) and 1 Pulse output Fieldbus interface: HART, Modbus TCP/RTU Robust metal housing, suitable for demanding outdoor applications ...
Configuration via dedicated smartphone app is easy and most user-friendly. It offers additional temperature sensor inputs and can therefore be used to monitor heat exchangers. It can be connected to any monitoring system thanks to various signal outputs: Modbus/RTU (standard), 4... 20 mA / Pulse / Alarm Relay (option), Modbus/TCP (option) Flow and consumption can be measured in both directions (bidirectional measurement) Can be used in stationary and portable applications Data logger files for the measurement log can be downloaded via USB. The mobile app provides an instant overview of daily, weekly, and monthly consumption in one click ...
Installation can be done in a few minutes. There is no process downtime during installation. No parts in contact with the fluid. No pressure loss, contamination or leakage during installation. Available pipe sizes: DN20, DN25, DN32, DN40 OLED display for parameter setting and measured values. 4... 20 mA and Modbus/RTU interface. Compact innovative design ...
Gases : 0..10 cm3/min-0..2500 l/min Tmax:50°C Pmax: 10 bar (35 bar optional) Connection:1/4"...1" Sensitivity: 1% Display: LCD Material: Tapcon,SS316 Output:4-20MA or 0-5 VDC ...
The sensor offers long-term stability and a wide measuring range. When the system is in operation, the sensor can be easily installed in the compressed air line via the ball valve. Ideal for FAD (Free Air Delivery) measurement at the compressor outlet. This method is used to see the actual performance of the compressor independent of ambient factors such as temperature, pressure, and humidity. Analog 4-20 mA + Pulse output, Modbus RTU or Modbus TCP communication options are available. With the included S4A software, you can monitor hourly, daily, or weekly consumption. With different shaft lengths, much larger diameters are possible (1''..20'') Can be used for high-temperature measurements up to 230 °C. Mechanically, there are no moving parts to wear and clog. All parts in contact with the flow medium are made of 316L stainless steel. All data can be measured in one sensor (flow rate, total consumption, speed, pressure, and temperature) In addition to wet and dry compressed air measurements, it can also be calibrated for other gases. ...
These compact sensors are ideal for measuring compressed air, nitrogen (N2), carbon dioxide (CO2), argon (Ar), oxygen (O2), hydrogen (H), natural gas, biogas, propane, butane and LPG. Integrated digital display showing instantaneous flow rate and total consumption, 4...20 mA Analog + Pulse output, RS 485, Modbus RTU Communication support, Five different thread connection sizes from DN8 up to DN32, ...